CABERRY
Sound Insulation & Noise Reduction Coating
Sound Insulation & Noise Reduction Coating
Не удалось загрузить сведения о доступности самовывоза
Share
Sound Insulation & Noise Reduction Coating
Acoustic Damping Soundproof Coating for Interior & Exterior Building
Caberry Sound Insulation & Noise Reduction Coating is a functional acoustic coating for building surfaces. It effectively absorbs and dampens vibration noise, reduces sound transmission, and delivers stable sound insulation performance for both indoor and outdoor construction projects. It can be directly sprayed or brushed on substrates and works perfectly with sound barrier systems.
This soundproof coating is widely used in traffic noise control, architectural acoustic renovation, entertainment venues and residential noise reduction projects.
- Residential buildings, interior wall & ceiling sound insulation
- Highway and tunnel noise control
- Road sound absorption and noise barrier panels
- Hotels, school auditoriums, gymnasiums
- Theatres, concert halls and conference reception rooms
- Indoor & exterior wall, ceiling acoustic treatment
1. Construction ambient temperature must not be lower than 5°C.
2. Ready for spray application once the bucket is opened.
Excellent Noise Damping Performance
Absorbs vibration and medium-high frequency noise, reduces reverberation and sound transmission through solid structures.
Sprayable & Easy Construction
Ready-to-use formula, no complicated pre-mixing. Can be sprayed, rolled or brushed on most stable substrates.
Suitable for Indoor & Outdoor
Good weather resistance, works for both interior acoustic renovation and outdoor traffic noise barrier projects.
Strong Substrate Adhesion
Bonds firmly to concrete, metal, cement boards and other common building substrates, not easy to peel off.
Environment Friendly Formula
Low odor, non-toxic raw material, compliant with international environmental requirements for public buildings.
Customizable Color
Color can be adjusted to match your project design and surrounding environment.
| Item | Specification |
|---|---|
| Product Name | Sound Insulation & Noise Reduction Coating |
| Application Method | Airless spray, roller, brush |
| Construction Temperature | ≥ 5°C |
| Appearance | Thick paste / liquid, custom color |
| Theoretical Coverage | 1.0–1.6 kg / ㎡ (depends on target sound reduction grade) |
| Dry to Touch | 2–4 h @ 25℃, 50% RH |
| Full Curing | 24–48 hours |
| Sound Reduction Grade | Customized by coating thickness & system design |
| Shelf Life | 12 months in original sealed bucket |
Note: Acoustic performance depends on coating thickness, substrate and whole acoustic system. All data tested under standard lab environment.
- Surface preparation: Remove dust, grease and loose layers, keep substrate solid and stable.
- Apply primer for porous concrete or cement substrates if needed.
- First coat of sound insulation coating.
- Add reinforcing fabric for high vibration areas (optional).
- Second or multiple coats to reach required sound reduction target.
- Do not construct when temperature below 5°C, heavy rain, heavy fog or dew.
- Stir fully before application.
- Spray method is preferred for uniform thickness and better acoustic effect.
- Control wet film thickness according to your acoustic design requirement.
- Use protective mask, gloves and goggles during construction.
- Package: 20kg / plastic bucket; private label & customized packaging available.
- Storage: Keep sealed, cool & dry, avoid freezing and direct sunlight.
- Trade Terms: EXW / FOB Guangzhou / CIF / DDP available.
We can provide full documents for tender, import clearance and project approval:
- ✅ TDS (Technical Data Sheet)
- ✅ MSDS / SDS Safety Data Sheet
- ✅ Acoustic noise reduction test report
- ✅ Factory ISO & environmental compliance documents
Custom colors are supported to match sound barrier, facade and interior decoration style. Trial sample bucket can be supplied for acoustic test before bulk order.
Sample policy: Sample cost and freight will be on buyer’s side.
Q: Can this coating reduce traffic noise for tunnel and highway barrier?
A: Yes, it is specially designed for vibration and noise reduction of road & tunnel sound barrier systems.
Q: Can I spray it directly after opening?
A: Yes, the product is ready for spraying after opening and proper stirring.
Q: What is the minimum construction temperature?
A: The construction environment temperature cannot be lower than 5°C.
Q: Can it be used on ceiling for home theater or meeting room?
A: Yes, it works well for ceiling and wall acoustic treatment of auditoriums, theatres and meeting rooms.
Q: What is your MOQ and lead time?
A: Standard MOQ negotiable; production lead time normally 7–15 working days after deposit.
Q: Can you provide English TDS and MSDS?
A: Yes, we provide full English technical documents for customs and project inspection.
👉 Contact Us for Acoustic Project Quotation
Request TDS, MSDS, noise test report, bulk price and shipping quotation for your sound insulation project.
WhatsApp: +86 13189072286 Email: caberrymay@gmail.com