CABERRY
Steel Structure Fire Protection Coating Manufacturer | CABERRY
Steel Structure Fire Protection Coating Manufacturer | CABERRY
Verfügbarkeit für Abholungen konnte nicht geladen werden
Share
Steel Structure Fire Protection Coating Manufacturer
CABERRY Steel Structure Fire Protection Coating is designed for passive fire protection of structural steel components in commercial buildings, industrial facilities and public infrastructure projects.
Available in thin-type and thick-type product options, the coating is developed for steel beams, steel columns, steel trusses and other structural steel members. The appropriate coating system should be selected according to the required fire resistance performance, building environment and project specifications.
Thin-Type Fire Protection Coating
A thin-film product option for projects requiring a relatively smooth coating appearance on exposed structural steel. Confirm its intumescent mechanism and approved application system with the manufacturer.
Thick-Type Fire Protection Coating
A thick-film product option for structural steel fire protection applications. Its suitability and fire resistance performance must be verified against the corresponding test documentation.
Direct Factory Supply | OEM & ODM | Bulk Orders | Technical Documentation | Export Support
Steel Fireproof Coating Product Overview
CABERRY provides steel structure fire protection coating in industrial packaging for construction contractors, building material distributors and engineering projects.
CABERRY steel structure fire protection coating for industrial and commercial construction projects.
How Does Steel Structure Fire Protection Coating Work?
Steel structures can lose their load-bearing capacity when exposed to high temperatures during a fire. Fire protection coatings are used as part of a passive fire protection system to delay the heating of structural steel and help maintain structural performance for the specified fire resistance period.
Intumescent Fire Protection
An intumescent coating reacts to high temperatures and expands to form an insulating char layer. This expanded layer reduces heat transfer to the underlying steel.
Thick-Film Thermal Protection
Certain thick-film fire protection systems provide thermal insulation through a comparatively thicker protective layer. The actual mechanism depends on the product formulation.
Important: The two working mechanisms above describe general fire protection technologies. Confirm the actual mechanism of each CABERRY product grade before specifying it for an engineering project.
Applications of Fire Resistant Coating for Steel Structures
Steel fire protection coatings are used in a wide range of commercial, industrial and infrastructure projects.
Commercial Buildings
Steel beams, columns and structural frameworks in office buildings, shopping malls, exhibition centers and commercial complexes.
Industrial Facilities
Steel structures in manufacturing plants, warehouses, petrochemical facilities and power plant buildings, subject to the specified fire exposure conditions.
Public Infrastructure
Steel trusses, structural frames and supporting components in airports, stadiums, railway stations and metro facilities.
Steel Fabrication Projects
Structural steel members, fabricated steel beams, columns and other steel components requiring a specified passive fire protection system.
Structural steel fire protection applications in industrial and commercial construction.
Key Features of CABERRY Steel Fire Protection Coating
01. Steel Surface Adhesion
Designed for application on appropriately prepared and primed steel substrates. Primer compatibility should be confirmed before construction.
02. Multiple Application Methods
Airless spraying is suitable for large-area construction. Brush and roller application can be used for appropriate smaller areas, edges and repair work.
03. Thin and Thick Product Options
Different product types can be considered according to structural design, coating requirements and project specifications.
04. Construction Flexibility
Mechanical mixing and adjustable application procedures help support consistent construction when the manufacturer's instructions are followed.
05. Primer System Compatibility
An appropriate anti-corrosion primer system is required. The primer must be approved for use with the selected fire protection coating.
06. Project-Based Technical Support
Product selection and application guidance can be discussed according to steel member types and project requirements.
Steel Structure Fireproof Coating Technical Specifications
The following table identifies the main technical information required for product selection and engineering evaluation.
| Technical Item | Product Information |
|---|---|
| Product Name | Steel Structure Fire Protection Coating |
| Manufacturer | CABERRY |
| Product Grades | Thin Type / Thick Type |
| Appearance | Confirm according to product grade |
| Product Composition | To be confirmed by the manufacturer |
| Density | Refer to the applicable product TDS |
| Solid Content | Refer to the applicable product TDS |
| Fire Resistance Rating | Subject to the corresponding test report |
| Dry Film Thickness (DFT) | Project-specific approved coating schedule |
| Wet Film Thickness (WFT) | According to the applicable product TDS |
| Theoretical Coverage | To be confirmed according to density and solids content |
| Surface Preparation | Sa 2.5, as specified for the existing product system |
| Primer | Compatible approved anti-corrosion primer |
| Application | Airless Spray / Brush / Roller |
| Mixing | Mechanical mixing until uniform |
| Maturation Time | 10–15 minutes, subject to TDS confirmation |
| Shelf Life | 12 months in sealed storage, subject to confirmation |
| Packaging | Industrial plastic bucket |
Technical values must be completed using the official TDS and relevant fire resistance test reports. Do not use an estimated fire rating or generic coating thickness as a certified product specification.
How to Apply Fireproof Paint on Structural Steel
Proper substrate preparation, compatible primer, controlled coating thickness and curing conditions are important for a reliable steel fire protection system.
Step 1. Steel Surface Preparation
Remove rust, oil, dust and other contaminants. The existing product instructions specify Sa 2.5 surface preparation. Inspect the steel surface before applying the primer.
Step 2. Apply Compatible Anti-Rust Primer
Apply an approved anti-corrosion primer to the prepared steel substrate. Confirm primer compatibility with the selected fire protection coating.
Step 3. Mechanical Mixing
Mechanically stir the coating according to the manufacturer's mixing instructions until the material is uniform and free of lumps. The existing product instructions specify a 10–15 minute maturation period.
Step 4. Coating Application
Airless spraying is recommended for suitable large-area projects. Brush or roller application can be used for smaller areas, edges and repair work where permitted by the TDS.
Step 5. Film Thickness Inspection
Control wet film thickness during application and verify dry film thickness after curing. Follow the approved loading schedule for each structural steel member.
Step 6. Curing and Final Inspection
Allow each coat to cure according to the manufacturer's technical instructions. Inspect coating continuity, thickness, adhesion and surface condition before acceptance.
Steel surface preparation, primer application and fire protection coating construction.
Fire Resistance Requirements for Structural Steel
Fire protection performance must be evaluated according to the building code, structural member geometry, required fire resistance period and the tested coating system.
Internationally used fire protection assessment references include:
- ASTM E119 – Fire Tests of Building Construction and Materials.
- UL 263 – Fire Tests of Building Construction and Materials.
- EN 13381-8 – Assessment of the Contribution to the Fire Resistance of Structural Members.
- AS 1530.4 – Fire Resistance Tests of Elements of Construction.
- GB 14907 – Fire Resistive Coatings for Steel Structures.
These are reference standards, not a declaration that this CABERRY product has passed each test. Product-specific certificates and test reports must be checked before project approval.
Required dry film thickness is not a universal fixed value. It depends on the fire resistance period, steel section factor, critical steel temperature and the applicable tested system. Obtain the approved coating thickness schedule for each structural member.
Technical Documents for International Buyers
Technical Data Sheet (TDS)
Product specifications, application instructions, recommended film thickness and technical properties.
Safety Data Sheet (SDS)
Product composition information, handling, storage and safety recommendations.
Fire Resistance Test Report
Product-specific third-party testing and assessment documents, where available.
Factory Quality Documentation
Relevant batch quality inspection records and manufacturing documentation.
Contact CABERRY to request available English technical documents and confirm the documentation required for your destination market.
Steel Fire Protection Coating Manufacturer in China
CABERRY is a building materials manufacturer based in Guangzhou, China. We support overseas distributors, importers, contractors and construction material wholesalers.
Factory Direct Supply
Direct communication with the manufacturer for bulk procurement and project requirements.
OEM & ODM Service
Customized packaging, product labels and branding solutions according to confirmed product capabilities.
Export Packaging
Industrial plastic bucket packaging. Packaging size and export arrangements can be confirmed before ordering.
International Logistics
EXW, FOB Guangzhou and other agreed international trade terms can be discussed.
Steel Structure Fireproof Coating FAQ
1. What is steel structure fire protection coating?
It is a passive fire protection material applied to structural steel components to delay heat transfer and help maintain the structural performance of steel members during fire exposure.
2. What is the difference between thin-type and thick-type fireproof coating?
Thin-type and thick-type products differ in coating build, formulation and application requirements. Their fire protection mechanisms and performance must be confirmed using the relevant product technical documentation.
3. Can steel fire protection paint be applied by airless spray?
The existing CABERRY product instructions identify airless spraying as a suitable application method for large areas. Brush and roller application are also listed for suitable smaller areas and repairs.
4. Is an anti-rust primer required before application?
The current CABERRY product instructions specify an anti-rust primer before applying the coating. The selected primer must be compatible with the fire protection system.
5. How thick should the fireproof coating be?
The required dry film thickness depends on the tested product system, structural steel section factor, target fire resistance period and project design. Request the applicable technical loading schedule.
6. Can this product be used for outdoor steel structures?
Outdoor suitability must be verified for the selected product grade and complete coating system. Confirm weather resistance, corrosion protection and topcoat requirements before outdoor use.
7. Can CABERRY supply samples and bulk orders?
CABERRY supports sample discussions, factory supply and bulk procurement. Contact our team to confirm sample availability, packaging and order quantities.
8. Can you provide TDS, SDS and fire test reports?
Available technical and safety documents can be requested from CABERRY. Fire resistance reports must be confirmed for the exact product grade and applicable test standard.
Get a Quote for Steel Structure Fire Protection Coating
Looking for a steel fireproof coating manufacturer in China? Contact CABERRY for product information, technical documents, samples and bulk quotations.
Please provide your product type, project application, required fire resistance rating and estimated quantity.
WhatsApp: +86 13189072286 Request Product Information by Email
Email: caberrymay@gmail.com
Manufacturer: Guangzhou Jiabaili Waterproof Engineering Co., Ltd.
Brand: CABERRY