{"product_id":"steel-structure-fire-protection-coating-manufacturer-caberry","title":"Steel Structure Fire Protection Coating Manufacturer | CABERRY","description":"\n\u003cdiv class=\"caberry-fire-page\"\u003e\n\n\u003cstyle\u003e\n.caberry-fire-page{\n  font-family:Arial,Helvetica,sans-serif;\n  color:#263445;\n  line-height:1.75;\n  max-width:1200px;\n  margin:auto;\n  font-size:15px;\n}\n.caberry-fire-page *{box-sizing:border-box}\n.caberry-fire-page h2{\n  color:#123d35;\n  font-size:27px;\n  line-height:1.35;\n  margin:0 0 16px;\n}\n.caberry-fire-page h3{\n  color:#087c55;\n  font-size:19px;\n  margin:0 0 10px;\n}\n.caberry-fire-page p{margin:0 0 13px}\n.caberry-fire-page .cf-section{\n  padding:34px 22px;\n  border-bottom:1px solid #e7eee9;\n}\n.caberry-fire-page .cf-eyebrow{\n  color:#07965d;\n  font-size:12px;\n  font-weight:bold;\n  letter-spacing:2px;\n  text-transform:uppercase;\n  margin-bottom:9px;\n}\n.caberry-fire-page .cf-hero{\n  background:#f1f8f4;\n  padding:34px 24px;\n  border-radius:12px;\n}\n.caberry-fire-page .cf-grid{\n  display:grid;\n  grid-template-columns:repeat(2,minmax(0,1fr));\n  gap:20px;\n}\n.caberry-fire-page .cf-card{\n  padding:21px;\n  background:#f5f8f6;\n  border-radius:9px;\n  height:100%;\n}\n.caberry-fire-page .cf-highlight{\n  color:#087b4e;\n  font-weight:bold;\n}\n.caberry-fire-page .cf-image{\n  width:100%;\n  height:auto;\n  display:block;\n  border-radius:9px;\n  margin:18px auto;\n}\n.caberry-fire-page .cf-image-note{\n  color:#65746e;\n  font-size:13px;\n  text-align:center;\n  margin-top:-9px;\n  margin-bottom:18px;\n}\n.caberry-fire-page .cf-table-wrap{\n  overflow-x:auto;\n  margin-top:15px;\n}\n.caberry-fire-page table{\n  border-collapse:collapse;\n  width:100%;\n  min-width:480px;\n  font-size:14px;\n}\n.caberry-fire-page th{\n  background:#087c55;\n  color:#fff;\n  text-align:left;\n  padding:13px;\n}\n.caberry-fire-page td{\n  border:1px solid #e2eae5;\n  padding:12px;\n  vertical-align:top;\n}\n.caberry-fire-page tr:nth-child(even){\n  background:#f5f8f6;\n}\n.caberry-fire-page .cf-step{\n  border-left:4px solid #0b9a60;\n  padding:13px 17px;\n  margin:14px 0;\n  background:#f5f9f6;\n  border-radius:0 7px 7px 0;\n}\n.caberry-fire-page .cf-cta{\n  background:#07583e;\n  color:white;\n  text-align:center;\n  padding:32px 22px;\n  border-radius:11px;\n}\n.caberry-fire-page .cf-cta h2,\n.caberry-fire-page .cf-cta h3{color:white}\n.caberry-fire-page .cf-cta a{\n  display:inline-block;\n  background:#fff;\n  color:#07583e;\n  padding:12px 22px;\n  border-radius:5px;\n  text-decoration:none;\n  font-weight:bold;\n  margin:7px 5px;\n}\n.caberry-fire-page .cf-note{\n  background:#fff8e9;\n  border-left:4px solid #e4a32a;\n  padding:15px;\n  font-size:13px;\n}\n.caberry-fire-page .cf-faq{\n  padding:17px 0;\n  border-bottom:1px solid #e3eae5;\n}\n.caberry-fire-page .cf-faq h3{font-size:16px}\n@media(max-width:700px){\n  .caberry-fire-page .cf-grid{grid-template-columns:1fr}\n  .caberry-fire-page .cf-section{padding:25px 13px}\n  .caberry-fire-page .cf-hero{padding:24px 15px}\n  .caberry-fire-page h2{font-size:23px}\n}\n\u003c\/style\u003e\n\n\u003c!-- 01 PRODUCT OVERVIEW --\u003e\n\u003csection class=\"cf-section cf-hero\"\u003e\n  \u003cdiv class=\"cf-eyebrow\"\u003eCABERRY · INDUSTRIAL FIRE PROTECTION MATERIALS\u003c\/div\u003e\n  \u003ch2\u003eSteel Structure Fire Protection Coating Manufacturer\u003c\/h2\u003e\n\n  \u003cp\u003e\n    CABERRY Steel Structure Fire Protection Coating is designed\n    for passive fire protection of structural steel components\n    in commercial buildings, industrial facilities and public\n    infrastructure projects.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    Available in thin-type and thick-type product options,\n    the coating is developed for steel beams, steel columns,\n    steel trusses and other structural steel members.\n    The appropriate coating system should be selected according\n    to the required fire resistance performance, building\n    environment and project specifications.\n  \u003c\/p\u003e\n\n  \u003cdiv class=\"cf-grid\"\u003e\n    \u003cdiv class=\"cf-card\"\u003e\n      \u003ch3\u003eThin-Type Fire Protection Coating\u003c\/h3\u003e\n      \u003cp\u003e\n        A thin-film product option for projects requiring\n        a relatively smooth coating appearance on exposed\n        structural steel. Confirm its intumescent mechanism\n        and approved application system with the manufacturer.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cf-card\"\u003e\n      \u003ch3\u003eThick-Type Fire Protection Coating\u003c\/h3\u003e\n      \u003cp\u003e\n        A thick-film product option for structural steel\n        fire protection applications. Its suitability and\n        fire resistance performance must be verified\n        against the corresponding test documentation.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cp class=\"cf-highlight\"\u003e\n    Direct Factory Supply | OEM \u0026amp; ODM | Bulk Orders |\n    Technical Documentation | Export Support\n  \u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003c!-- 02 PRODUCT IMAGE --\u003e\n\u003csection class=\"cf-section\"\u003e\n  \u003cdiv class=\"cf-eyebrow\"\u003ePRODUCT PRESENTATION\u003c\/div\u003e\n  \u003ch2\u003eSteel Fireproof Coating Product Overview\u003c\/h2\u003e\n\n  \u003cp\u003e\n    CABERRY provides steel structure fire protection coating\n    in industrial packaging for construction contractors,\n    building material distributors and engineering projects.\n  \u003c\/p\u003e\n\n  \u003c!-- Replace with the actual Shopify CDN product image URL --\u003e\n  \u003cimg class=\"cf-image\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0864\/4041\/1438\/files\/Fireproof_Paint_for_Structural_Steel.png?v=1795745314\" alt=\"CABERRY steel structure fire protection coating in blue industrial packaging\"\u003e\n\n  \u003cp class=\"cf-image-note\"\u003e\n    CABERRY steel structure fire protection coating\n    for industrial and commercial construction projects.\n  \u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003c!-- 03 WORKING PRINCIPLE --\u003e\n\u003csection class=\"cf-section\"\u003e\n  \u003cdiv class=\"cf-eyebrow\"\u003ePRODUCT TECHNOLOGY\u003c\/div\u003e\n  \u003ch2\u003eHow Does Steel Structure Fire Protection Coating Work?\u003c\/h2\u003e\n\n  \u003cp\u003e\n    Steel structures can lose their load-bearing capacity\n    when exposed to high temperatures during a fire.\n    Fire protection coatings are used as part of a passive\n    fire protection system to delay the heating of structural\n    steel and help maintain structural performance for\n    the specified fire resistance period.\n  \u003c\/p\u003e\n\n  \u003cdiv class=\"cf-grid\"\u003e\n    \u003cdiv class=\"cf-card\"\u003e\n      \u003ch3\u003eIntumescent Fire Protection\u003c\/h3\u003e\n      \u003cp\u003e\n        An intumescent coating reacts to high temperatures\n        and expands to form an insulating char layer.\n        This expanded layer reduces heat transfer to\n        the underlying steel.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cf-card\"\u003e\n      \u003ch3\u003eThick-Film Thermal Protection\u003c\/h3\u003e\n      \u003cp\u003e\n        Certain thick-film fire protection systems provide\n        thermal insulation through a comparatively thicker\n        protective layer. The actual mechanism depends\n        on the product formulation.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cp class=\"cf-note\"\u003e\n    Important: The two working mechanisms above describe\n    general fire protection technologies. Confirm the actual\n    mechanism of each CABERRY product grade before specifying\n    it for an engineering project.\n  \u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003c!-- 04 APPLICATION AREAS --\u003e\n\u003csection class=\"cf-section\"\u003e\n  \u003cdiv class=\"cf-eyebrow\"\u003eAPPLICATION AREAS\u003c\/div\u003e\n  \u003ch2\u003eApplications of Fire Resistant Coating for Steel Structures\u003c\/h2\u003e\n\n  \u003cp\u003e\n    Steel fire protection coatings are used in a wide range\n    of commercial, industrial and infrastructure projects.\n  \u003c\/p\u003e\n\n  \u003cdiv class=\"cf-grid\"\u003e\n    \u003cdiv class=\"cf-card\"\u003e\n      \u003ch3\u003eCommercial Buildings\u003c\/h3\u003e\n      \u003cp\u003e\n        Steel beams, columns and structural frameworks\n        in office buildings, shopping malls, exhibition\n        centers and commercial complexes.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cf-card\"\u003e\n      \u003ch3\u003eIndustrial Facilities\u003c\/h3\u003e\n      \u003cp\u003e\n        Steel structures in manufacturing plants,\n        warehouses, petrochemical facilities and\n        power plant buildings, subject to the\n        specified fire exposure conditions.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cf-card\"\u003e\n      \u003ch3\u003ePublic Infrastructure\u003c\/h3\u003e\n      \u003cp\u003e\n        Steel trusses, structural frames and supporting\n        components in airports, stadiums, railway\n        stations and metro facilities.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cf-card\"\u003e\n      \u003ch3\u003eSteel Fabrication Projects\u003c\/h3\u003e\n      \u003cp\u003e\n        Structural steel members, fabricated steel beams,\n        columns and other steel components requiring\n        a specified passive fire protection system.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cimg class=\"cf-image\" src=\"REPLACE_WITH_STEEL_STRUCTURE_APPLICATION_IMAGE_URL\" alt=\"Fire protection coating applied to structural steel beams and columns in an industrial building\"\u003e\n\n  \u003cp class=\"cf-image-note\"\u003e\n    Structural steel fire protection applications in\n    industrial and commercial construction.\n  \u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003c!-- 05 PRODUCT ADVANTAGES --\u003e\n\u003csection class=\"cf-section\"\u003e\n  \u003cdiv class=\"cf-eyebrow\"\u003ePRODUCT FEATURES\u003c\/div\u003e\n  \u003ch2\u003eKey Features of CABERRY Steel Fire Protection Coating\u003c\/h2\u003e\n\n  \u003cdiv class=\"cf-grid\"\u003e\n    \u003cdiv class=\"cf-card\"\u003e\n      \u003ch3\u003e01. Steel Surface Adhesion\u003c\/h3\u003e\n      \u003cp\u003e\n        Designed for application on appropriately prepared\n        and primed steel substrates. Primer compatibility\n        should be confirmed before construction.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cf-card\"\u003e\n      \u003ch3\u003e02. Multiple Application Methods\u003c\/h3\u003e\n      \u003cp\u003e\n        Airless spraying is suitable for large-area\n        construction. Brush and roller application\n        can be used for appropriate smaller areas,\n        edges and repair work.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cf-card\"\u003e\n      \u003ch3\u003e03. Thin and Thick Product Options\u003c\/h3\u003e\n      \u003cp\u003e\n        Different product types can be considered\n        according to structural design, coating\n        requirements and project specifications.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cf-card\"\u003e\n      \u003ch3\u003e04. Construction Flexibility\u003c\/h3\u003e\n      \u003cp\u003e\n        Mechanical mixing and adjustable application\n        procedures help support consistent construction\n        when the manufacturer's instructions are followed.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cf-card\"\u003e\n      \u003ch3\u003e05. Primer System Compatibility\u003c\/h3\u003e\n      \u003cp\u003e\n        An appropriate anti-corrosion primer system\n        is required. The primer must be approved\n        for use with the selected fire protection coating.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cf-card\"\u003e\n      \u003ch3\u003e06. Project-Based Technical Support\u003c\/h3\u003e\n      \u003cp\u003e\n        Product selection and application guidance\n        can be discussed according to steel member\n        types and project requirements.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003c!-- 06 TECHNICAL DATA --\u003e\n\u003csection class=\"cf-section\"\u003e\n  \u003cdiv class=\"cf-eyebrow\"\u003eTECHNICAL DATA SHEET\u003c\/div\u003e\n  \u003ch2\u003eSteel Structure Fireproof Coating Technical Specifications\u003c\/h2\u003e\n\n  \u003cp\u003e\n    The following table identifies the main technical\n    information required for product selection and\n    engineering evaluation.\n  \u003c\/p\u003e\n\n  \u003cdiv class=\"cf-table-wrap\"\u003e\n    \u003ctable\u003e\n      \u003cthead\u003e\n        \u003ctr\u003e\n          \u003cth\u003eTechnical Item\u003c\/th\u003e\n          \u003cth\u003eProduct Information\u003c\/th\u003e\n        \u003c\/tr\u003e\n      \u003c\/thead\u003e\n      \u003ctbody\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eProduct Name\u003c\/td\u003e\n          \u003ctd\u003eSteel Structure Fire Protection Coating\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eManufacturer\u003c\/td\u003e\n          \u003ctd\u003eCABERRY\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eProduct Grades\u003c\/td\u003e\n          \u003ctd\u003eThin Type \/ Thick Type\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eAppearance\u003c\/td\u003e\n          \u003ctd\u003eConfirm according to product grade\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eProduct Composition\u003c\/td\u003e\n          \u003ctd\u003eTo be confirmed by the manufacturer\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eDensity\u003c\/td\u003e\n          \u003ctd\u003eRefer to the applicable product TDS\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eSolid Content\u003c\/td\u003e\n          \u003ctd\u003eRefer to the applicable product TDS\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eFire Resistance Rating\u003c\/td\u003e\n          \u003ctd\u003eSubject to the corresponding test report\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eDry Film Thickness (DFT)\u003c\/td\u003e\n          \u003ctd\u003eProject-specific approved coating schedule\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eWet Film Thickness (WFT)\u003c\/td\u003e\n          \u003ctd\u003eAccording to the applicable product TDS\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eTheoretical Coverage\u003c\/td\u003e\n          \u003ctd\u003eTo be confirmed according to density and solids content\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eSurface Preparation\u003c\/td\u003e\n          \u003ctd\u003eSa 2.5, as specified for the existing product system\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003ePrimer\u003c\/td\u003e\n          \u003ctd\u003eCompatible approved anti-corrosion primer\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eApplication\u003c\/td\u003e\n          \u003ctd\u003eAirless Spray \/ Brush \/ Roller\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eMixing\u003c\/td\u003e\n          \u003ctd\u003eMechanical mixing until uniform\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eMaturation Time\u003c\/td\u003e\n          \u003ctd\u003e10–15 minutes, subject to TDS confirmation\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eShelf Life\u003c\/td\u003e\n          \u003ctd\u003e12 months in sealed storage, subject to confirmation\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003ePackaging\u003c\/td\u003e\n          \u003ctd\u003eIndustrial plastic bucket\u003c\/td\u003e\n        \u003c\/tr\u003e\n      \u003c\/tbody\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\n  \u003cp class=\"cf-note\"\u003e\n    Technical values must be completed using the official\n    TDS and relevant fire resistance test reports.\n    Do not use an estimated fire rating or generic coating\n    thickness as a certified product specification.\n  \u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003c!-- 07 CONSTRUCTION --\u003e\n\u003csection class=\"cf-section\"\u003e\n  \u003cdiv class=\"cf-eyebrow\"\u003eAPPLICATION GUIDE\u003c\/div\u003e\n  \u003ch2\u003eHow to Apply Fireproof Paint on Structural Steel\u003c\/h2\u003e\n\n  \u003cp\u003e\n    Proper substrate preparation, compatible primer,\n    controlled coating thickness and curing conditions\n    are important for a reliable steel fire protection system.\n  \u003c\/p\u003e\n\n  \u003cdiv class=\"cf-step\"\u003e\n    \u003ch3\u003eStep 1. Steel Surface Preparation\u003c\/h3\u003e\n    \u003cp\u003e\n      Remove rust, oil, dust and other contaminants.\n      The existing product instructions specify Sa 2.5\n      surface preparation. Inspect the steel surface\n      before applying the primer.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"cf-step\"\u003e\n    \u003ch3\u003eStep 2. Apply Compatible Anti-Rust Primer\u003c\/h3\u003e\n    \u003cp\u003e\n      Apply an approved anti-corrosion primer to the\n      prepared steel substrate. Confirm primer compatibility\n      with the selected fire protection coating.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"cf-step\"\u003e\n    \u003ch3\u003eStep 3. Mechanical Mixing\u003c\/h3\u003e\n    \u003cp\u003e\n      Mechanically stir the coating according to the\n      manufacturer's mixing instructions until the\n      material is uniform and free of lumps.\n      The existing product instructions specify\n      a 10–15 minute maturation period.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"cf-step\"\u003e\n    \u003ch3\u003eStep 4. Coating Application\u003c\/h3\u003e\n    \u003cp\u003e\n      Airless spraying is recommended for suitable\n      large-area projects. Brush or roller application\n      can be used for smaller areas, edges and\n      repair work where permitted by the TDS.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"cf-step\"\u003e\n    \u003ch3\u003eStep 5. Film Thickness Inspection\u003c\/h3\u003e\n    \u003cp\u003e\n      Control wet film thickness during application\n      and verify dry film thickness after curing.\n      Follow the approved loading schedule for each\n      structural steel member.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"cf-step\"\u003e\n    \u003ch3\u003eStep 6. Curing and Final Inspection\u003c\/h3\u003e\n    \u003cp\u003e\n      Allow each coat to cure according to the\n      manufacturer's technical instructions.\n      Inspect coating continuity, thickness,\n      adhesion and surface condition before acceptance.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cimg class=\"cf-image\" src=\"REPLACE_WITH_APPLICATION_PROCESS_IMAGE_URL\" alt=\"Steel structure fireproof coating application process including surface preparation primer and spray application\"\u003e\n\n  \u003cp class=\"cf-image-note\"\u003e\n    Steel surface preparation, primer application\n    and fire protection coating construction.\n  \u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003c!-- 08 FIRE PERFORMANCE --\u003e\n\u003csection class=\"cf-section\"\u003e\n  \u003cdiv class=\"cf-eyebrow\"\u003eFIRE PERFORMANCE \u0026amp; COMPLIANCE\u003c\/div\u003e\n  \u003ch2\u003eFire Resistance Requirements for Structural Steel\u003c\/h2\u003e\n\n  \u003cp\u003e\n    Fire protection performance must be evaluated according\n    to the building code, structural member geometry,\n    required fire resistance period and the tested\n    coating system.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    Internationally used fire protection assessment\n    references include:\n  \u003c\/p\u003e\n\n  \u003cul\u003e\n    \u003cli\u003eASTM E119 – Fire Tests of Building Construction and Materials.\u003c\/li\u003e\n    \u003cli\u003eUL 263 – Fire Tests of Building Construction and Materials.\u003c\/li\u003e\n    \u003cli\u003eEN 13381-8 – Assessment of the Contribution to the Fire Resistance of Structural Members.\u003c\/li\u003e\n    \u003cli\u003eAS 1530.4 – Fire Resistance Tests of Elements of Construction.\u003c\/li\u003e\n    \u003cli\u003eGB 14907 – Fire Resistive Coatings for Steel Structures.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003cp\u003e\n    These are reference standards, not a declaration\n    that this CABERRY product has passed each test.\n    Product-specific certificates and test reports\n    must be checked before project approval.\n  \u003c\/p\u003e\n\n  \u003cp class=\"cf-note\"\u003e\n    Required dry film thickness is not a universal\n    fixed value. It depends on the fire resistance\n    period, steel section factor, critical steel\n    temperature and the applicable tested system.\n    Obtain the approved coating thickness schedule\n    for each structural member.\n  \u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003c!-- 09 QUALITY DOCUMENTS --\u003e\n\u003csection class=\"cf-section\"\u003e\n  \u003cdiv class=\"cf-eyebrow\"\u003eQUALITY DOCUMENTATION\u003c\/div\u003e\n  \u003ch2\u003eTechnical Documents for International Buyers\u003c\/h2\u003e\n\n  \u003cdiv class=\"cf-grid\"\u003e\n    \u003cdiv class=\"cf-card\"\u003e\n      \u003ch3\u003eTechnical Data Sheet (TDS)\u003c\/h3\u003e\n      \u003cp\u003e\n        Product specifications, application instructions,\n        recommended film thickness and technical properties.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cf-card\"\u003e\n      \u003ch3\u003eSafety Data Sheet (SDS)\u003c\/h3\u003e\n      \u003cp\u003e\n        Product composition information, handling,\n        storage and safety recommendations.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cf-card\"\u003e\n      \u003ch3\u003eFire Resistance Test Report\u003c\/h3\u003e\n      \u003cp\u003e\n        Product-specific third-party testing and\n        assessment documents, where available.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cf-card\"\u003e\n      \u003ch3\u003eFactory Quality Documentation\u003c\/h3\u003e\n      \u003cp\u003e\n        Relevant batch quality inspection records\n        and manufacturing documentation.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cp\u003e\n    Contact CABERRY to request available English\n    technical documents and confirm the documentation\n    required for your destination market.\n  \u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003c!-- 10 PACKAGING --\u003e\n\u003csection class=\"cf-section\"\u003e\n  \u003cdiv class=\"cf-eyebrow\"\u003eMANUFACTURING \u0026amp; EXPORT\u003c\/div\u003e\n  \u003ch2\u003eSteel Fire Protection Coating Manufacturer in China\u003c\/h2\u003e\n\n  \u003cp\u003e\n    CABERRY is a building materials manufacturer\n    based in Guangzhou, China. We support overseas\n    distributors, importers, contractors and\n    construction material wholesalers.\n  \u003c\/p\u003e\n\n  \u003cdiv class=\"cf-grid\"\u003e\n    \u003cdiv class=\"cf-card\"\u003e\n      \u003ch3\u003eFactory Direct Supply\u003c\/h3\u003e\n      \u003cp\u003e\n        Direct communication with the manufacturer\n        for bulk procurement and project requirements.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cf-card\"\u003e\n      \u003ch3\u003eOEM \u0026amp; ODM Service\u003c\/h3\u003e\n      \u003cp\u003e\n        Customized packaging, product labels and\n        branding solutions according to confirmed\n        product capabilities.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cf-card\"\u003e\n      \u003ch3\u003eExport Packaging\u003c\/h3\u003e\n      \u003cp\u003e\n        Industrial plastic bucket packaging.\n        Packaging size and export arrangements\n        can be confirmed before ordering.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cf-card\"\u003e\n      \u003ch3\u003eInternational Logistics\u003c\/h3\u003e\n      \u003cp\u003e\n        EXW, FOB Guangzhou and other agreed\n        international trade terms can be discussed.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003c!-- 11 FAQ --\u003e\n\u003csection class=\"cf-section\"\u003e\n  \u003cdiv class=\"cf-eyebrow\"\u003eFREQUENTLY ASKED QUESTIONS\u003c\/div\u003e\n  \u003ch2\u003eSteel Structure Fireproof Coating FAQ\u003c\/h2\u003e\n\n  \u003cdiv class=\"cf-faq\"\u003e\n    \u003ch3\u003e1. What is steel structure fire protection coating?\u003c\/h3\u003e\n    \u003cp\u003e\n      It is a passive fire protection material applied\n      to structural steel components to delay heat transfer\n      and help maintain the structural performance of\n      steel members during fire exposure.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"cf-faq\"\u003e\n    \u003ch3\u003e2. What is the difference between thin-type and thick-type fireproof coating?\u003c\/h3\u003e\n    \u003cp\u003e\n      Thin-type and thick-type products differ in coating\n      build, formulation and application requirements.\n      Their fire protection mechanisms and performance\n      must be confirmed using the relevant product\n      technical documentation.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"cf-faq\"\u003e\n    \u003ch3\u003e3. Can steel fire protection paint be applied by airless spray?\u003c\/h3\u003e\n    \u003cp\u003e\n      The existing CABERRY product instructions identify\n      airless spraying as a suitable application method\n      for large areas. Brush and roller application\n      are also listed for suitable smaller areas and repairs.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"cf-faq\"\u003e\n    \u003ch3\u003e4. Is an anti-rust primer required before application?\u003c\/h3\u003e\n    \u003cp\u003e\n      The current CABERRY product instructions specify\n      an anti-rust primer before applying the coating.\n      The selected primer must be compatible with\n      the fire protection system.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"cf-faq\"\u003e\n    \u003ch3\u003e5. How thick should the fireproof coating be?\u003c\/h3\u003e\n    \u003cp\u003e\n      The required dry film thickness depends on the\n      tested product system, structural steel section\n      factor, target fire resistance period and\n      project design. Request the applicable\n      technical loading schedule.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"cf-faq\"\u003e\n    \u003ch3\u003e6. Can this product be used for outdoor steel structures?\u003c\/h3\u003e\n    \u003cp\u003e\n      Outdoor suitability must be verified for the\n      selected product grade and complete coating system.\n      Confirm weather resistance, corrosion protection\n      and topcoat requirements before outdoor use.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"cf-faq\"\u003e\n    \u003ch3\u003e7. Can CABERRY supply samples and bulk orders?\u003c\/h3\u003e\n    \u003cp\u003e\n      CABERRY supports sample discussions, factory\n      supply and bulk procurement. Contact our team\n      to confirm sample availability, packaging\n      and order quantities.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"cf-faq\"\u003e\n    \u003ch3\u003e8. Can you provide TDS, SDS and fire test reports?\u003c\/h3\u003e\n    \u003cp\u003e\n      Available technical and safety documents can\n      be requested from CABERRY. Fire resistance\n      reports must be confirmed for the exact product\n      grade and applicable test standard.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003c!-- 12 INQUIRY --\u003e\n\u003csection class=\"cf-section\"\u003e\n  \u003cdiv class=\"cf-cta\"\u003e\n    \u003cdiv class=\"cf-eyebrow\" style=\"color:#c5f1d7\"\u003e\n      DIRECT FACTORY INQUIRY\n    \u003c\/div\u003e\n\n    \u003ch2\u003eGet a Quote for Steel Structure Fire Protection Coating\u003c\/h2\u003e\n\n    \u003cp\u003e\n      Looking for a steel fireproof coating manufacturer\n      in China? Contact CABERRY for product information,\n      technical documents, samples and bulk quotations.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      Please provide your product type, project application,\n      required fire resistance rating and estimated quantity.\n    \u003c\/p\u003e\n\n    \u003ca href=\"https:\/\/wa.me\/8613189072286\" target=\"_blank\" rel=\"noopener\"\u003e\n      WhatsApp: +86 13189072286\n    \u003c\/a\u003e\n\n    \u003ca href=\"mailto:caberrymay@gmail.com\"\u003e\n      Request Product Information by Email\n    \u003c\/a\u003e\n\n    \u003cp style=\"font-size:13px;margin-top:15px\"\u003e\n      Email: caberrymay@gmail.com\u003cbr\u003e\n      Manufacturer: Guangzhou Jiabaili Waterproof Engineering Co., Ltd.\u003cbr\u003e\n      Brand: CABERRY\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003c\/div\u003e\n","brand":"CABERRY","offers":[{"title":"Default Title","offer_id":68190359453998,"sku":null,"price":150.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0864\/4041\/1438\/files\/Fireproof_Paint_for_Structural_Steel.png?v=1795745314","url":"https:\/\/caberry88.com\/pl\/products\/steel-structure-fire-protection-coating-manufacturer-caberry","provider":"CABERRY","version":"1.0","type":"link"}